Compteur D'eau Woltman Diamètre 400 mm
Dimensions
Type | Dimension | L Longeur | H Hauteur | Connecting Flange | |||
D1 Diamètre extérieur | D2 Diamètre du cercle de boulonnage | Boulons de connexion(n-M) | Pression de travail (MPa) | ||||
mm | |||||||
LXLC-350 | 350 | 500 | 590 | 505 | 460 | 16-M20 | 1.0 |
520 | 470 | 16-M24 | 1.6 | ||||
LXLC-400 | 400 | 600 | 660 | 565 | 515 | 16-M24 | 1.0 |
580 | 525 | 16-M27 | 1.6 | ||||
LXLC-450 | 450 | 600 | 700 | 615 | 565 | 20-M24 | 1.0 |
640 | 585 | 20-M27 | 1.6 | ||||
LXLC-500 | 500 | 800 | 760 | 670 | 620 | 20-M24 | 1.0 |
715 | 650 | 20-M30 | 1.6 | ||||
LXLC-600 | 600 | 800 | 880 | 780 | 725 | 20-M27 | 1.0 |
840 | 770 | 20-M33 | 1.6 |
NOTE: The flange dimension conforms to ISO70052:1988 standard.
Flange standard can be customized. Order for products of special requirements is also accepted.
Specifications Techniques Principales
Type |
Dimensions (mm) |
Classe | Qs Débit Max | Qp Débit Permanent | Qt Débit de transition | Qmin Débit Min. | Lecture Min. | Lecture Max. |
m³/h | m³ | |||||||
LXLC -350 |
350 | A |
1600 |
800 | 240 | 64 |
0.02 |
999,999,999 |
B | 160 | 24 | ||||||
LXLC -400 |
400 | A |
2000 |
1000 | 300 | 80 |
0.02 |
999,999,999 |
B | 200 | 30 | ||||||
LXLC -450 |
450 | A |
2000 |
1000 | 300 | 80 |
0.02 |
999,999,999 |
B | 200 | 30 | ||||||
LXLC -500 |
500 | A |
3000 |
1500 | 450 | 120 |
0.02 |
999,999,999 |
B | 300 | 45 | ||||||
LXLC -600 |
600 | A |
6000 |
3000 | 900 | 240 |
0.02 |
999,999,999 |
B | 600 | 90 |
Application
Mesurer le volume d'eau froide (chaude) traversant le pipeline.
Caractéristiques
Structure d'élément amovible, installation et maintenance faciles,registre pour une utilisation universelle dans cette gamme détachable sans retirer le compteur du pipeline.
Cadran sec, action sensible à l'entraînement magnétique, perte de pression faible.
Le registre scellé sous vide garantit que le cadran reste exempt de buée et garde la lecture claire pour un service à long terme.
Matériaux sélectionnés de haute qualité pour une caractéristique stable et fiable.
Données techniques conformes à la norme internationale ISO 4064.
Caractéristiques Optionales
Registre en plastique, en cuivre et registre en plein verre.
Ratio: R=50.
Dimension: DN50-600mm.
Eau froide/chaude.
Option interrupteur Reed.
Flange standard peut être choisie.
La rotation à 360 degrés peut être choisie.
Fonte, fonte ductile, SS304, corps SS316 peuvent être choisis.
Pression de travail: PN16/25.
La couleur peut être changée sur le corps et la couverture.
Conditions de Travail
Température de l’eau: 0.1℃~50℃ ( 0.1℃~90℃ pour compteur d’eau chaude).
Pression de l’eau: PN10/16/25.
Erreur maximale Tolérée
Dans la zone inférieure de qmin inclus jusqu'à mais non compris qt est ±5 %.
Dans la zone supérieure de qt inclus jusqu'à et y compris qs est ±2% (±3% pour compteur d'eau chaude).
Vue Eclatée
Description du Fonctionnement du Système à Deux Interrupteur REED
Veuillez voir le schéma du système à deux interrupteurs REED ci-dessous, les deux interrupteurs REED seraient respectivement actionnés "ON" OU "OFF" par l'aimant fixé à l'aiguille ou à l'engrenage pendant son fonctionnement sur le registre, mais jamais "ON" à la même temps, à moins que l'aimant n'attaque.
Les deux interrupteurs REED fonctionnent deux "ON" et deux "OFF" dans un tour du pointeur ou l'engrenage signifie une sortie de signal, ce principe empêche la perte ou le surcomptage de la sortie du signal en raison du jonglage des interrupteurs ou de la vibration du tuyau, donc assure la fiabilité de la sortie du signal.
Garantie
All meteTous les compteurs seront garantis contre les défauts de fabrication et de matériaux pendant une période d'un (1) an à compter de la date de réception. Les compteurs ou les pièces défectueux découverts au cours de cette période doivent être remplacés sans frais lors du retour chez S.H.Meters.
Compteur D'eau Woltman Diamètre 400 mm
Dimensions
Type | Dimension | L Longeur | H Hauteur | Connecting Flange | |||
D1 Diamètre extérieur | D2 Diamètre du cercle de boulonnage | Boulons de connexion(n-M) | Pression de travail (MPa) | ||||
mm | |||||||
LXLC-350 | 350 | 500 | 590 | 505 | 460 | 16-M20 | 1.0 |
520 | 470 | 16-M24 | 1.6 | ||||
LXLC-400 | 400 | 600 | 660 | 565 | 515 | 16-M24 | 1.0 |
580 | 525 | 16-M27 | 1.6 | ||||
LXLC-450 | 450 | 600 | 700 | 615 | 565 | 20-M24 | 1.0 |
640 | 585 | 20-M27 | 1.6 | ||||
LXLC-500 | 500 | 800 | 760 | 670 | 620 | 20-M24 | 1.0 |
715 | 650 | 20-M30 | 1.6 | ||||
LXLC-600 | 600 | 800 | 880 | 780 | 725 | 20-M27 | 1.0 |
840 | 770 | 20-M33 | 1.6 |
NOTE: The flange dimension conforms to ISO70052:1988 standard.
Flange standard can be customized. Order for products of special requirements is also accepted.
Specifications Techniques Principales
Type |
Dimensions (mm) |
Classe | Qs Débit Max | Qp Débit Permanent | Qt Débit de transition | Qmin Débit Min. | Lecture Min. | Lecture Max. |
m³/h | m³ | |||||||
LXLC -350 |
350 | A |
1600 |
800 | 240 | 64 |
0.02 |
999,999,999 |
B | 160 | 24 | ||||||
LXLC -400 |
400 | A |
2000 |
1000 | 300 | 80 |
0.02 |
999,999,999 |
B | 200 | 30 | ||||||
LXLC -450 |
450 | A |
2000 |
1000 | 300 | 80 |
0.02 |
999,999,999 |
B | 200 | 30 | ||||||
LXLC -500 |
500 | A |
3000 |
1500 | 450 | 120 |
0.02 |
999,999,999 |
B | 300 | 45 | ||||||
LXLC -600 |
600 | A |
6000 |
3000 | 900 | 240 |
0.02 |
999,999,999 |
B | 600 | 90 |
Application
Mesurer le volume d'eau froide (chaude) traversant le pipeline.
Caractéristiques
Structure d'élément amovible, installation et maintenance faciles,registre pour une utilisation universelle dans cette gamme détachable sans retirer le compteur du pipeline.
Cadran sec, action sensible à l'entraînement magnétique, perte de pression faible.
Le registre scellé sous vide garantit que le cadran reste exempt de buée et garde la lecture claire pour un service à long terme.
Matériaux sélectionnés de haute qualité pour une caractéristique stable et fiable.
Données techniques conformes à la norme internationale ISO 4064.
Caractéristiques Optionales
Registre en plastique, en cuivre et registre en plein verre.
Ratio: R=50.
Dimension: DN50-600mm.
Eau froide/chaude.
Option interrupteur Reed.
Flange standard peut être choisie.
La rotation à 360 degrés peut être choisie.
Fonte, fonte ductile, SS304, corps SS316 peuvent être choisis.
Pression de travail: PN16/25.
La couleur peut être changée sur le corps et la couverture.
Conditions de Travail
Température de l’eau: 0.1℃~50℃ ( 0.1℃~90℃ pour compteur d’eau chaude).
Pression de l’eau: PN10/16/25.
Erreur maximale Tolérée
Dans la zone inférieure de qmin inclus jusqu'à mais non compris qt est ±5 %.
Dans la zone supérieure de qt inclus jusqu'à et y compris qs est ±2% (±3% pour compteur d'eau chaude).
Vue Eclatée
Description du Fonctionnement du Système à Deux Interrupteur REED
Veuillez voir le schéma du système à deux interrupteurs REED ci-dessous, les deux interrupteurs REED seraient respectivement actionnés "ON" OU "OFF" par l'aimant fixé à l'aiguille ou à l'engrenage pendant son fonctionnement sur le registre, mais jamais "ON" à la même temps, à moins que l'aimant n'attaque.
Les deux interrupteurs REED fonctionnent deux "ON" et deux "OFF" dans un tour du pointeur ou l'engrenage signifie une sortie de signal, ce principe empêche la perte ou le surcomptage de la sortie du signal en raison du jonglage des interrupteurs ou de la vibration du tuyau, donc assure la fiabilité de la sortie du signal.
Garantie
All meteTous les compteurs seront garantis contre les défauts de fabrication et de matériaux pendant une période d'un (1) an à compter de la date de réception. Les compteurs ou les pièces défectueux découverts au cours de cette période doivent être remplacés sans frais lors du retour chez S.H.Meters.
ADRESSE
TÉLÉPHONE |